- SMREF.TXT Headings:
- 1.0 Appendix A Advanced Utilities
- 1.1 About SiteMeter's Utilities
- 1.1.1 Utilities List
- 1.2 Swatcher TSR Method
- 1.2.1 Loading Swatcher
- 1.2.2 Note About Swatcher
- 1.2.3 Running DSW
- 1.2.4 What DSW Does
- 1.2.5 Potential DSW Problems
- 1.3 SYSMOD
- 1.3.1 What is SYSMOD?
- 1.3.2 Using SYSMOD
- 1.3.3 Functionality
- 1.3.4 ADDDEVICE [DeviceToAdd][Key][Option]
- 1.3.5 ADDLINE [LineToAdd][Key][Option]
- 1.3.6 ADDPATH [PathKey][DirectoryKey][Option]
- 1.3.7 CFGSETSTRONG [Key][NewValue]
- 1.3.8 REPLACEKEY [Key][DelKey][NewItem]
- 1.3.9 REPLACELINE [Key][NewLine]
- 1.3.10 WRITEINISTR [SectionName][KeyName][NewValue]
- 1.3.11 Halting SYSMOD Updates
- 1.4 SLOCK/SUNLOCK
- 1.4.1 Using SLOCK & SUNLOCK
- 1.4.2 Command Line Reference
- 1.4.3 Error Levels
- 1.4.4 SLOCK Errorlevels
- 1.4.5 SUNLOCK Errorlevels
- 2.0 Appendix B Troubleshooting
- 2.1 Error Messages
- 2.2 Troubleshooting
- 2.2.1 Installation and Set Up
- 2.2.2 Cannot Meter
- 2.2.3 LockSet Does Not Release
- 2.2.4 SMRUP Patches
- 2.2.5 SMRNLM.EXE 73,092 6-02-94
- 2.2.6 SMRUP3.EXE 05-25-94 1,788,902 11:48a
- 2.2.7 SiteMeter Reports (Sreport.exe)
- 2.2.8 BTRIEVE
- 2.2.9 Changing the SiteMeter Messages
-
-
- 1.0 Appendix A Advanced Utilities
-
- Chapter 8 described the monitoring features available for network
- users. This appendix explains how to use SiteMeter's advanced utilities.
-
-
- 1.1 About SiteMeter's Utilities
-
- The utilities described in this chapter are provided for you if you have
- decided not to use the SiteMeter Proxy NLM as the metering and file
- protection method for your LAN.
-
- 1.1.1 Utilities List
-
- The following lists the utilities described in this chapter:
- o SWATCHER
- o DSW
- o SYSMOD
- o SUNLOCK
- o SLOCK
- Each of these utilities is fully explained in the following sections.
-
-
- 1.2 Swatcher TSR Method
-
- If you have chosen to use the Swatcher TSR method of metering and file
- protecting your LAN, you may need to become familiar with the following
- metering utilities:
- o Swatcher
- o DSW
-
- Swatcher is a TSR and must be loaded in order to properly meter and
- protect the files on your LAN.
-
- 1.2.1 Loading Swatcher
-
- Swatcher must be loaded from the DOS prompt. To load Swatcher type:
- Swatcher <ENTER>
- Swatcher must be loaded AFTER loading IPX and NETX shells. It should
- not be loaded high; it should be in conventional memory.
-
- We recommend loading Swatcher from the AUTOEXEC.BAT before logging in to
- the network.
-
- NOTE: DO NOT LOAD Swatcher.com via the NetWare login scripts (either
- personal or system), as inconsistent and/or inappropriate metering behavior
- may result.
-
- If you try to load Swatcher after login and the Security Scan Interval is
- set and you have a lengthy login script, you may be disconnected before you
- get a chance to load Swatcher.
-
- 1.2.2 Note About Swatcher
-
- Since membership in a group determines local drive access, SiteMeter must
- know who you are when you load Swatcher. This can only be accomplished if
- Swatcher is loaded AFTER you log in. For security reasons, however, you may
- prefer that Swatcher is loaded BEFORE login time. To address this, we have
- created DSW.COM. Users can load Swatcher before logging in, but at this time
- SiteMeter cannot identify the users and therefore will not restrict access
- to local drives.
-
- ONCE a user is logged in, you must run DSW.COM; it reads the CURRENT server's
- information about how it should handle the user's local drives and then
- changes Swatcher accordingly. DSW is only able to update Swatcher ONE
- TIME--the FIRST time it is run.
-
- Further attempts to run DSW do not change Swatcher, although you receive a
- message on the screen indicating that it has updated Swatcher.
-
- 1.2.3 Running DSW
-
- DSW is run through the system Login Script. Here is a sample login script:
- MAP F:=FS/SYS:LOGIN
- DRIVE F:
- #DSW
-
- 1.2.4 What DSW Does
-
- DSW reads the information the server holds about a user, including whether
- to disable his or her local drives completely, disable only his or her
- local .EXE and .COM files, or give the him or her FULL rights.
-
- This information is sent to Swatcher. Swatcher receives it and updates its
- values accordingly.
-
- 1.2.5 Potential DSW Problems
-
- If more than one person uses the same PC and these people have different
- local drive rights, a problem could arise.
-
- SCENARIO 1: Person A (in local drives disabled group) loads Swatcher, logs
- in, and Swatcher is updated. Person B (who has full rights) logs in to the
- same PC that Person A was using. Because Swatcher is NOT updated again,
- Person B does not get access to the drives.
-
- Person B must reboot and reload Swatcher to get the appropriate rights.
-
- SCENARIO 2: Person A (with Full Rights) logs out. Person B (with no rights)
- logs into the same PC and now has full rights to the local drives.
-
- To prevent this problem, the PC should be re-booted between users.
-
- 1.3 SYSMOD
-
- 1.3.1 What is SYSMOD?
-
- SYSMOD is a McAfee utility designed to help network administrators edit
- files. With SYSMOD, you can edit users' files without going from workstation
- to workstation to do so.
-
- This utility is installed in the directories SITEMETR or BWORKS and
- PUBLIC. You can use SYSMOD if you prefer to edit your users' files manually.
-
- 1.3.2 Using SYSMOD
-
- Use the following procedure to implement the SYSMOD program:
-
- Make sure that the path to the .INI files is included as either a
- search drive in the case of users' Windows residing on the network
- or in the users' path statements located in their AUTOEXEC.BAT
- files for local Windows on the C: drive.
-
- Example lines for login script:
- Map ins s16:=SYS:\USER\%LOGIN_NAME\WINDOWS
- INCLUDE SYS:PUBLIC\SMRUSER.BAT
- Example line for the SMRUSER.BAT using the INCLUDE command:
- SYSMOD WIN.INI REPLACEKEY LOAD SWATCHER.COM SWATCHER.COM
-
- 1.3.3 Functionality
-
- This section documents the SYSMOD program and its functionality.
-
- All SYSMOD functions follow a basic format:
- SYSMOD <filename.ext>functionName parameter1...parameterN
- Below is a list of functions and their associated parameters. An example is
- also provided for each function. Note that when a parameter can be Null, it
- must still be entered, but use the NULL keyword. For example,
- SYSMOD CONFIG.SYS ADDDEVICE C:\HIMEM.SYS NULL BEFORE
-
- This would place the device= line at the beginning of the file. (See
- ADDDEVICE for details.)
-
- The filename specified must exist; SYSMOD, however, will intelligently
- determine the location of the file for you. If you specify AUTOEXEC.BAT or
- CONFIG.SYS (with no path), SYSMOD will automatically look on your boot drive
- for the file. If you specify a filename with no path (e.g., SYSTEM.INI),
- SYSMOD will look in your path for the file. If you specify a full path to
- the file, SYSMOD will look in the explicit path for the file. If the file
- cannot be found, SYSMOD aborts with an error.
-
- 1.3.4 ADDDEVICE [DeviceToAdd][Key][Option]
-
- This function adds a new DEVICE= line to a system file (typically the DOS
- CONFIG.SYS). Specify the path and driver name in the DeviceToAdd
- (e.g., C:\WINDOWS\EMM386.EXE). Specify a key value to search for in Key
- (e.g., HIMEM.SYS), and where to place DeviceToAdd BEFORE or AFTER Key in
- Option. For example:
- SYSMOD CONFIG.SYS ADDDEVICE C:\WINDOWS\EMM386.EXE HIMEMSYS AFTER
- would place a "device=c:\windows\emm386.exe" after the "device=himem.sys"
- line in the CONFIG.SYS. If Key is NULL or the key specified is not found,
- the device line is added at the beginning or end of the file.
-
- 1.3.5 ADDLINE [LineToAdd][Key][Option]
-
- This function adds a line of text to a system file. Specify the entire line
- of text you wish to add in LineToAdd. Specify a reference key value in Key
- that you would like to position LineToAdd in reference to. Option (BEFORE or
- AFTER) specifies whether LineToAdd is placed BEFORE or AFTER Key. Again, if
- Key is NULL, then LineToAdd is placed at the beginning or the end of the file.
- For example,
- SYSMOD AUTOEXEC.BAT ADDLINE C:\DOS\SMARTDRV NETX AFTER
- would place a new line (c:\dos\smartdrv) after the line specifying netx
- (if found, otherwise it would go at the end of the file).
-
- 1.3.6 ADDPATH [PathKey][DirectoryKey][Option]
-
- This function adds a sub directory to a path environment variable.
- Specify the name of the path environment variable to edit (PATH for DOS, or
- DPATH for OS/2) in PathKey and the subdirectory to add in PathToAdd.
- DirectoryKey specifies the sub directory that PathToAdd will be placed
- BEFORE or AFTER. Option is either BEFORE or AFTER. If DirectoryKey is a null
- string, ADDPATH will place PathToAdd at the beginning or end (respectively)
- of the path statement. If the key specified in PathKey is not found, then a
- new one is added, with a "SET" prepended. This allows for adding path like
- environment variables such as "SET TEMP=," and so on.
-
- NOTE: This function can also be sued to edit other lines, such as a
- TEMP environment variable, or any other line that does something like "SET
- envvar>=d:\path." For example,
- SYSMOD AUTOEXEC.BAT PATH C:\WINDOWS C:\DOS BEFORE
- would place c:\windows in the path statement before c:\dos. If c:\dos isn't
- in the path, then c:\windows would be placed at the beginning of the path
- statement.
-
- 1.3.7 CFGSETSTRONG [Key][NewValue]
-
- This function sets a strong variable in a system file (e.g., STACKS 9,256,
- DOS=HIGH etc.). Specify the variable in Key and a string value to set in
- NewValue. For example,
- SYSMOD CONFIG.SYS CFGSETSTRING STACKS 9,256
- would set the value of the STACKS statement to 9,256.
-
- 1.3.8 REPLACEKEY [Key][DelKey][NewItem]
-
- This function works like REPLACELINE, except that it replaces a key value
- rather than the entire line. Use Key to locate the line, DelKey is the key
- value to replace, and NewItem is the new value.
-
- The new value can be NULL, in which case DelKey will be removed. For
- instance:
- SYSMOD WIN.INI REPLACEKEY LOAD SWINAPP.EXE SWATCHER.COM
- would replace the swinapp.exe reference in the load=line of the WIN.INI
- with swatcher.com.
-
- 1.3.9 REPLACELINE [Key][NewLine]
-
- This function replaces an existing line in a system file with a new line.
- Specify the key value of the line you wish to replace, such as PATH or
- COMSPEC (or DEVICE, for that matter) in Key. Specify the new value of the
- entire line in NewLine. If Parameter 2 is a null string, then the line will
- be deleted. For instance:
- SYSMOD AUTOEXEC.BAT REPLACELINE COMSPEC NULL
- would delete the existing COMSPEC line.
-
- 1.3.10 WRITEINISTR [SectionName][KeyName][NewValue]
-
- This function mimics the Windows API function WritePrivateProfileStrong0.
- It expects the file you're modifying to be in the Windows INI file format.
- This function writes NewValue to the INI file under SectionName in KeyName.
- However, if SectionName doesn't exist, then a whole new section is added to
- the end of the INI file, with a new key=value added in that section. If the
- section was found, but the KeyName wasn't found, the new key value is added
- directly after SectionName. For instance:
- SYSMOD SYSTEM.INI BOOT KEYBOARD.DRV BDIKBD.DRV
- would change the existing keyboard.drv= entry in the [boot] section
- of the system.ini to read keyboard.drv-bdikbd.drv.
-
- 1.3.11 Halting SYSMOD Updates
-
- This section describes how to stop SYSMOD from updating a user's files every
- time he or she logs in. To instruct SYSMOD to update a user's .ini file only
- once, add similar lines to the system login script:
- MAP F:=SYS:USER\%LOGIN_NAME
- #COMMAND /C SITE.BAT
- MAP DEL F:
- where site.bat is a .bat file with the following lines:
- if exist f:sitedone.doc goto end
- call smruser.bat
- copy sitedone.doc f:
- :end
- where sitedone.doc is a dummy text file that = 'sysmod has already run.'
-
- This code creates a flag that indicates if sysmod has already run.
- SYSMOD will see this and not run.
-
-
- 1.4 SLOCK/SUNLOCK
-
- This section explains how to use SiteMeter's SLOCK/SUNLOCK utilities
- for metering from a batch file. In this section, "LockSet" is a McAfee term
- for a metered application.
-
- NOTE: You must have Read, Write, Open, Create, Delete and Search rights
- in the directory where the SITEDATA file is stored if you wish to use
- SLOCK and SUNLOCK. The default home directory is SYS:SYSTEM\SITEMETR.
-
- SLOCK and SUNLOCK allow a user to secure or lock a position in the
- desired application and then free or unlock that position for
- another user. These commands should be included in batch files or
- other means such as a menu system setup.
-
- The following batch file consists of the appropriate SiteMeter commands to
- lock and unlock positions into the LockSet SYSCON. The batch file looks like
- this:
- SLOCK SYSCON* (where SYSCON is metered APP.Name)
- If errorlevel = 100 SYSCON
- SUNLOCK SYSCON * (where SYSCON is metered App. Name)
-
- NOTE: The errorlevel = 100 tests the return code from SLOCK. All return
- codes for SLOCK and SUNLOCK are listed later in this appendix. The
- asterisk (*) will display SLOCK messages.
-
- SYSCON is the metered application name as it appears in the metering
- definition. By requiring people to use a batch file to run SYSCON, you are
- modifying the way users operate that application, resulting in increased
- control over the network through SiteMeter, even without SWATCHER loaded.
-
- 1.4.1 Using SLOCK & SUNLOCK
-
- This section describes how to use SLOCK and SUNLOCK.
-
- Use the following procedure:
-
- 1. Create a LockSet for SYSCON.
-
- 2. Use your text editor to create a batch file called TEST.BAT.
-
- This batch file should contain the three lines from the previous section.
-
- 3. At the DOS prompt, type TEST <ENTER>.
-
- The first command in the batch file will now be executed. Once you
- have secured a position in the LockSet, the following message appears:
-
- Position has been obtained in LockSet SYSCON.
-
- At this point, the screen for SYSCON displays. You have now successfully
- gained access to SYSCON.
-
- 4. Exit the application.
-
- The command "SUNLOCK SYSCON" is executed as soon as you exit SYSCON.
- The following message appears:
-
- Your position has been released in LockSet SYSCON.
-
- The following batch file shows examples of using errorlevels in
- conjunction with SLOCK and SUNLOCK. Here, if the errorlevel returns
- a successful code, the software package Multimate will be accessed.
-
- If not successful, a message will appear on the screen telling the
- user that all the positions in the LockSet for Multimate are taken.
- At the end of each course, SUNLOCK will be executed, releasing the
- position in the LockSet.
- echo off
- SLOCK MULTIMATE
- if errorlevel= 100 goto go
- goto Again
- :go
- MMS.EXE (Multimate)
- goto end
- :Again
- echo 'Try later, Multimate is licensed out...'
- pause
- :end
- SUNLOCK MULTIMATE (metered application name)
-
- 1.4.2 Command Line Reference
-
- This section displays the correct syntax for SLOCK and SUNLOCK and
- explains the command line options.
-
- The correct syntax for SLOCK is:
- SLOCK LockSet [*] [S=fileserver]
-
- NOTE: The brackets indicate optional entries. Do NOT type the brackets
- when using these options.
-
- OPTION DESCRIPTION
- LOCKSET This is a required entry. The name of the LockSet must be
- entered. The LockSet is the metered application.
- * Displays message flag. Designating this option provides the
- user with visual confirmation that the commands have been
- executed.
- S=fileserver This option denotes the name of the fileserver that contains
- the LockSet.
-
- The correct syntax for SUNLOCK is:
- SUNLOCK LockSet [*] [S=fileserver]
-
- NOTE: The brackets indicate optional entries. Do NOT type the brackets when
- using these options.
-
- OPTION DESCRIPTION
- LOCKSET This is a required entry. The name of the LockSet must be
- entered. The LockSet is the metered application.
- * Displays message flag. Designating this option provides the
- user with visual confirmation that the commands have been
- executed.
- S=fileserver This option denotes the name of the fileserver that contains
- the LockSet.
-
- 1.4.3 Error Levels
-
- SiteMeter has two types of error reporting that can be printed to the screen:
- text messages and numeric codes. Not all programs contain both types of
- errors. This section explains the numeric codes.
-
- All programs will report with an on-screen message when there is an attempt
- to:
- o Execute the utility while not using Advanced NetWare
- o Use any of the utilities while not logged into the network (other
- than SWATCHER)
-
- Numeric code returns are offered for both SLOCK and SUNLOCK. The following
- sections list these codes.
-
- 1.4.4 SLOCK Errorlevels
-
- 100
- User has successfully obtained a position in the desired LockSet.
- 99
- Bad LockSet name or lock set name is too long.
- 88
- Invalid LockSet name or name does not exist.
- 77
- LockSet is in use by someone using SiteMeter to change some
- parameter about that set.
- 66
- After testing the LockSet 30 times, it is still locked (not by the
- Supervisor--77)
- 58
- No slots available in LockSet, you have been queued.
- 56
- No queue slots available (maximum of 8); you were not queued.
- 55
- No slots available in LockSet...try later.
- 50
- Not attached to specified server.
-
- 1.4.5 SUNLOCK Errorlevels
-
- 100
- User's slot has been successfully found and released.
- 99
- Bad LockSet name or LockSet name is too long.
- 88
- Invalid LockSet name; name does not exist.
- 77
- LockSet is in user by someone using SiteMeter to change a parameter
- about that LockSet.
- 66
- After testing the LockSet 30 times, it is still locked (not by
- Supervisor--error 77).
- 55
- No slot in use.
- 50
- Not attached to specified server.
- 33
- No rights to SYS:SYSTEM\SITEMETR, or it does not exist. The name
- (directory) is defined by the SiteMeter Administrator.
- 22
- No network drives are mapped. SUNLOCK 'borrows' one of the current
- station's network drive letters to update the activity log, but if
- none exist the activity log will not be updated.
-
-
-
- 2.0 Appendix B Troubleshooting
-
- Appendix A provided information about SiteMeter's advanced utilities. This
- appendix provides a listing of SiteMeter's error messages and their
- explanations as well as common troubleshooting tips.
-
-
- 2.1 Error Messages
-
- The following error messages may display while using SiteMeter.
-
- A print destination must be chosen.
- Please select a printer in the printer setup dialog box to run a
- report.
-
- A report type must be selected.
- Please specify a report type in the reports dialog box to run a
- report.
-
- A server must be selected.
- Please specify a server in the reports dialog box to run a report.
-
- A source file must be indicated.
- Please specify an input source in the reports dialog box to run a
- report.
-
- A valid date range must be provided.
- Please specify a date range for filter criteria in the reports
- dialog box to run a report.
-
- Are you sure you want to export the data?
- Choose the Yes button to continue with the export of the data file.
-
- At least one filter criteria choice must be given!
- Please specify at least one of the filter criteria, either date,
- user, or application.
-
- File size exceeds 65,535 lines. Unable to export.
- The data file is too big to be exported any of the standard formats.
- Please try Btrieve as the export type.
-
- Invalid user name supplied.
- Please specify a valid user name in the attach dialog box.
-
- No additional servers can be found.
- SiteMeter capability could not detect additional servers.
-
- No default printer! Select a printer from PRINT SETUP menu.
- Please select a printer in the printer setup dialog box to run a
- report.
-
- No input file specified. Cannot continue.
- Please specify the name of the input file.
-
- No output file specified. Cannot continue.
- Please specify the name of the output file on the export dialog box
- for data output.
-
- No output type specified. Cannot continue.
- Please select one of the output formats specified in the drop down
- list.
-
- No server specified. Cannot continue.
- Please select a server to generate reports.
-
- No source type specified. Cannot continue.
- Please specify one of the four radio buttons on the export dialog
- box for input source.
-
- Please select or enter a server name before pressing the OK pushbutton.
- Please specify a server in the attach or detach dialog box.
-
- Report setup choices incomplete.
- All selections necessary to run reports have not been made in the
- reports dialog box.
-
- The 'sitedata' file has been corrupted. Please contact McAfee Technical
- Support for assistance.
- Cannot read the SITEDATA file. Please contact McAfee Technical
- Support for assistance at 908-530-9650.
-
- Unable to establish connection with DataLIB DLL. Cannot continue.
- Please check to see that the file DLWBC31.DLL is in the same
- directory as SREPORT.EXE.
-
- Unable to initialize Btrieve DLL file.
- Please check and make sure that the files WBTRCALL.DLL and
- WBHANDLE.DLL are in the same directory as SREPORT.EXE.
-
- Unable to initialize DataLIB DLL; export functions will be unreliable.
- Please check to see that the file DLWBC31.DLL is in same directory
- as SREPORT.EXE.
-
- Unable to open input file. Cannot continue.
- Please check to see that the input files SITEDATA or VIRUSDTA are
- in the directory you have selected.
-
- Unable to open output file. Cannot continue.
- Please check to see that the file DLWBC31.DLL is in the same
- directory as SREPORT.EXE.
-
- When 'File' is the print destination, a file type must be selected.
- Please specify an output file name to print a report to a file.
-
- Would you like to export new baseline source files for your report?
- Choose the Yes button to continue with the export of the data files.
- You may choose the No button if you have recently exported the data
- files. This will save some time in the report generation process.
-
- Unable to create Btrieve output file. File may be in use.
- The Btrieve data output file with extension .DAT may already be in
- use by another user. Ensure that no one else is using the file and
- try again. If the problem still persists, please use the Btrieve
- utility provided by NetWare. Type BUTIL -RESET filename.DAT.
-
- Unable to create peaks.dat file.
- The Btrieve data output file PEAKS.DAT may already be in use by
- another user. Ensure that no one else is using the file and try
- again. If the problem still persists, please use the Btrieve utility
- provided by NetWare. Type BUTIL -RESET PEAKS.DAT.
-
- Unable to initialize Btrieve requester.
- Btrieve requester Brequester may not be running. Please exit Windows
- and run BREQUEST.EXE.
-
- Unable to insert Btrieve record.
- Btrieve was unable to insert one of the records in the export
- process. The original file may be corrupted, please call McAfee
- Technical Support.
-
- Unable to open peaks.dat file.
- The Btrieve data output file PEAKS.DAT may already be in use by
- another user. Ensure that no one else is using the file and try
- again. If the problem still persists, please use the Btrieve utility
- provided by NetWare. Type BUTIL -RESET PEAKS.DAT.
-
- Unable to open sitedata.dat file.
- The Btrieve data output file SITEDATA.DAT may already be in use by
- another user. Ensure that no one else is using the file and try again.
- If the problem still persists, please use the Btrieve
- utility provided by NetWare. Type BUTIL -RESET SITEDATA.DAT.
-
-
- 2.2 Troubleshooting
-
- This section describes solutions to some of the common difficulties
- encountered with SiteMeter.
-
- 2.2.1 Installation and Set Up
-
- Please see the Quick Start Guide in Chapter 3 for instructions on
- installation and setup. Chapter 2 provides detailed installation
- instructions and error messages.
-
- 2.2.2 Cannot Meter
-
- This section provides a checklist of things to do if you are unable to
- meter software on your network. An example of this problem would be when a
- user runs an application but SiteMeter does not show the software as active
- in View Application Usage or in the Usage.exe program.
-
- Follow the items on this checklist:
- 1. Check if the NLMs are loaded and active. Go into Administration,
- Metering, View Metering Status.
-
- 2. Try placing a full path into the filename field when defining the
- metered application. If that does not work, try without a path and
- just a filename.
-
- 3. Check if the NetWare drivers are up to date (at a minimum they should
- be IPX v. 3.10, NETX v. 3.26, IPXODI v. 2.10, LSL v. 2.01).
-
- 4. If the user is loading SWATCHER, make sure it is loaded low. Swatcher
- is only designed to be loaded into conventional memory (640K).
-
- 5. Check for additional, interfering TSRs or drivers. Do a MEM /C | MORE
- to see what is loaded in memory and strip the PC of all TSR's and
- drivers besides the NetWare drivers and whatever is absolutely necessary
- for Windows.
-
- To do this, rename the autoexec.bat file to autoexec.old and remove from
- the config.sys file all unnecessary drivers. For instance, WordPerfect
- Office v. 3.1's Notify TSR may prevent a DOS application from releasing
- the lockset.
-
- 6. Check the win.ini file's load= statement. Test with only NWPOPUP on
- the load= statement.
-
- 7. SPAWNING. Check if the file that is being metered is SPAWNING.
-
- A file that spawns opens up one file, closes it and then opens up a
- different file. For example, WordPerfect For Windows v. 5.1 first opens
- WPWIN.EXE. It then closes WPWIN.EXE and opens or spawns to WPWINFIL.EXE.
- This means that WPWINFIL.EXE is the file to meter for WordPerfect
- For Windows. To check for what file to meter, run RCONSOLE or walk over
- to the fileserver console. Run Monitor. Then List Active Connections and
- select Connection Information. Select the name of the user. Then have
- the user run the application. The files that remain open in Monitor for
- that user's PC will be displayed and you will be able to identify the
- files running for the application.
-
- As of this writing, SiteMeter v. 4.1.1 or earlier requires that an .exe
- or .com file must be open in order to meter an application. The secondary
- file or files that are spawned may not have an .exe or .com extension and
- this sometimes results in the application not metering or the lockset not
- being released when the application is closed. If this is the case and the
- application is a DOS based program, SLOCK and SUNLOCK may be used to meter
- the program. SLOCK and SUNLOCK are metering utilities which shipped
- with SiteLock. Simply create a batch file which runs SLOCK, the DOS
- application and then SUNLOCK. For example, let's say the program is
- SYSCON. The .bat file that would be set up could be called SYSCON.BAT.
- The contents of the .bat file would be,
- SLOCK SYSCON_UTIL
- SYSCON.EXE
- SUNLOCK SYSCON_UTIL
- where SYSCON_UTIL is the Metered Application Name in the Currently
- Metered Application under Metering. When the user types SYSCON,
- SYSCON.BAT will execute and SLOCK will run, manually placing a lock on
- the metered application. Then SYSCON.EXE will run. When the user exits
- SYSCON, SUNLOCK will run, manually releasing the lock in SiteMeter.
-
- NOTE: Spawning will be addressed by an enhancement in a future release of
- SiteMeter/BrightWorks. Please see the appropriate sections in Appendix A
- for further information on Slock and Sunlock.
-
- Another workaround is to list all of the .exe or .com files under
- File[s] To Meter in the metered application. This sometimes gets the
- application to meter properly and/or release the lockset. Especially
- try this with Windows based applications because there is no workaround
- like Sunlock to catch a spawned Windows based application.
-
- An additional workaround is to modify the SITEMETR.EXT file. The
- Sitemetr.ext file exists in the Home Directory For Data Files
- (SYS:SYSTEM\SITEMETR). It contains a listing of the extensions of
- the files that can be accepted as the File[s] To Meter in a
- metered application. By editing this file, the Supervisor (or
- equivalent) will then be able to enter a filename with the new
- file extension as a File[s] To Meter. It may then be possible to
- meter an application without a .exe or .com extension. In our
- experience, the only applications that were able to be metered
- this way were Micrographic programs. These programs include
- Designer, Draw and Charisma. These programs spawn to a .BIN file
- which SiteMeter cannot normally meter. The workaround for the
- SITEMETR.NLMs is as follows:
- a. Edit the SYS:\SYSTEM\SITEMETR\SITEMETR.EXT file and add
- .BIN to the list of file extensions.
- b. Enter (DESIGNER).BIN as the File[s] To Meter in the Currently
- Metered Application under SiteMeter (SYS:\DESIGNER\DESIGNER.BIN).
- NOTE: For SWATCHER, the workaround to meter Micrographics programs is
- quite different: Delete the original Designer.exe file and rename the
- Designer.bin file to Designer.exe. Copy that new .EXE file into the
- <MGXLIBS> subdirectory. Within File[s] To Meter include the specific
- path and correct .EXE file to protect. Other programs such as Draw and
- Charisma can do the same. Rename or delete the .EXE file and copy the
- .BIN file to a .EXE file.
-
- 8. Remove items from the Windows Startup group and test.
-
- 9. Reload the Sitemetr and Smrproxy NLMs.
-
- 10. If the SiteMeter NLMs are being loaded after Macintosh NLMs (AFP.NLM,
- ATPS.NLM), load the SiteMeter NLMs before the Macintosh NLMs. In the
- past, having the SiteMeter NLMs loaded after Macintosh NLMs sometimes
- caused the fileserver to crash and/or metering to fail.
-
- 11. Check if the old SiteLock NLM is simultaneously loaded with
- Sitemetr.nlm and Smrproxy.nlm. This could have disastrous, random
- results. If so, remove Sitelock.nlm.
-
- 12. Recreate the lockset. Go Metering, Currently Metered Applications and
- delete the entry for the software package that will not meter. Then add
- the entry back into the metering database and retest.
-
-
- 2.2.3 LockSet Does Not Release
-
- For example, a user enters Lotus 1-2-3. After exiting the program, View
- Application Usage or USAGE.EXE still shows the user in the application when
- they are not in the application.
-
- To troubleshoot this situation, usually the affected PC must first release
- the lockset. To do this, have the user with the locked application either
- back out of Windows or log out of the network.
-
- Follow this checklist to solve this problem:
- 1. Do one of the following:
- a.Place the full path into the File[s] To Meter field. For example,
- SYS:\PUBLIC\SYSCON.EXE. Go into Metering and Modify the currently
- metered application. 'Remove' the file that is already present and
- then 'Add' to Browse For Files To Meter. Make sure the Include Path
- box is marked. Then browse for the filename and it will appear in
- the File[s] To Meter window with the full path.
- b. If the path already exists in the File[s] To Meter field, remove
- the path and just leave the filename using similar steps as in 1a.
- For example, 123.EXE.
- Make sure the Include Path box is blank.
-
- 2. If the user has loaded the SWATCHER TSR, make sure that Swatcher is NOT
- loaded high. Swatcher was designed to only be loaded in conventional
- memory (640 K).
-
- 3. Check if the NLMs are loaded and active. Go Administration, Metering,
- View Metering Status.
-
- 4. Ensure that the user has loaded the latest NetWare drivers (IPX, IPXODI,
- LSL and NETX).
-
- 5. SPAWNING. Check if the application spawns other files.
- As of this writing, SiteMeter v. 4.1.1 or earlier requires an open .exe
- or .com file to meter an application. This will be addressed by an
- enhancement in a future release. The secondary file or files that are
- spawned may not have an .exe or .com extension and this sometimes
- results in the lockset not being released when the application is metered.
- If this is the case and the application is a DOS based program, SUNLOCK
- may be used to release the lockset. SUNLOCK is a metering utility which
- shipped with SiteLock. Simply create a batch file which runs the DOS
- application and then runs SUNLOCK. For example, lets say the program is
- SYSCON. The .bat file that would be set up could be called SYSCON.BAT.
- The contents of the .bat file would be,
- SYSCON.EXE
- SUNLOCK SYSCON_UTIL
- where SYSCON_UTIL is the Metered Application Name in the Currently
- Metered Application under Metering. When the user types SYSCON,
- SYCON.BAT will execute and SYSCON.EXE will run. When the user exits
- SYSCON, SUNLOCK will run, manually releasing the lockset in SiteMeter.
- Please see Appendix A for further information.
-
- Another workaround is to list all of the .exe or .com files under
- File[s] To Meter in the metered application. This sometimes gets the
- application to meter properly and release the lockset. Especially try
- this with Windows based applications, because there is no workaround
- like Sunlock to catch a spawned Windows based application.
-
- 6. Check for additional, interfering TSRs or drivers. Do a MEM /C | MORE
- to see what has been loaded into memory and strip the PC of all TSR's
- and drivers besides the NetWare drivers and whatever is absolutely
- necessary for Windows.
-
- To do this, rename the autoexec.bat file to autoexec.old and remove from
- the config.sys file all unnecessary drivers. For instance, WordPerfect
- Office v. 3.1's Notify TSR may prevent a DOS application from releasing
- the lockset.
-
- 7. Remove items from the Windows Startup group and test.
-
- 8. Check the PC's win.ini file's load= statement. Test with only NWPOPUP
- on the load= statement.
-
- 9. Check if the old SiteLock NLM is simultaneously loaded with Sitemetr.nlm
- and Smrproxy.nlm.
-
- This could have disastrous results. If the Sitelock.nlm is loaded,
- REMOVE the Sitelock.nlm from the fileserver's memory and the autoexec.ncf
- file.
-
- 10. Recreate the lockset.
-
- Go Metering, Currently Metered Applications and delete the entry for the
- software package that will not meter. Then add the entry back into the
- metering database and retest.
-
- 11. QEMM v. 7.01. Can't release a lockset for an application that is called
- off an attached server due to QEMM v. 7.01. The workaround is to remove
- the LOADHI command from the SHELL= line in the workstation's CONFIG.SYS.
- QEMM's v7.xx of Optimize places this LOADHI command on the SHELL= line.
- Apparently, previous versions of Optimize did not do this.
-
- 12. DR DOS v. 6.0. It is suspected that you can't release a lockset on a
- PC running DR DOS v. 6.0. Use a different type of DOS.
-
- NOTE: This problem also applied to DOS applications run under Windows.
-
- 13. NET-PROT. It is possible that with the NETPROT.NLM v. 1.23 loaded,
- intermittently locksets do not release or SiteMeter fails to meter.
-
- Results from in-house testing revealed that locksets on DOS applications
- are not released. This only seems to occur if an active virus scan is
- being performed by Net-Prot. Locksets on Windows applications seem to
- meter fine but will occasionally not be released. This does not seem to
- follow any pattern. However, if an active virus scan is being performed
- by Net-Prot, SiteMeter will NOT release locksets. This issue is
- currently under investigation.
-
-
- 2.2.4 SMRUP Patches
-
- The following sections describe the various patches available for SiteMeter.
-
- 2.2.5 SMRNLM.EXE 73,092 6-02-94
-
- SMRNLM.EXE only contains the current SiteMeter NLMs, current
- SMRAGENT.EXE file and the current SITEMETR.MSG file (along with a
- read me file SMRNLM.DOC). SMRNLM.EXE supports versions of SiteMeter
- v. 4.00 or greater. The updated version of SMRAGENT.EXE included
- here addresses an "out of memory" message that could display in
- Windows (Occurred with SMRAGENT 3-09-94). If a user needs only the
- current NLMs or SMRAGENT, SMRNLM.EXE is the file to use.
- o 351108 05-04-94 12:12 SITEMETR.NLM
- o 21168 04-01-94 13:26 SMRAGENT.EXE
- o 74972 05-04-94 12:18 SMRPROXY.NLM
- o 1439 02-10-94 10:29 SITEMETR.MSG
- o 3557 06-02-94 SMRNLM.DOC
-
- Other items SMRNLM.EXE addresses:
- 1. Sometimes cannot meter or virus protect applications run from a map
- rooted drive.
-
- 2. SMRPROXY NLM cannot be loaded without first disabling NetWare Accounting.
-
- 3. The fileserver would sometimes abend upon a DOWN command.
-
- 4. Sometimes a SPX socket problem occurred with SMRAGENT 8-17-93.
-
- This sometimes occurred with other programs that open SPX sockets
- inside Windows such as a mail TSR or Windows For Workgroups. Symptoms
- include, "SiteMeter agent Error 7: There was an IPX Problem
- communicating with server" or "Wcnwlib error: Unexpected error opening
- socket" or PC lock ups. This problem also results in "Error 001: cannot
- communicate with VAP or NLM" with the SiteLock Swrap feature.
-
- 5. IPX Traffic.
-
- Sometimes when the 7-20-93 Sitemetr.nlm and the 8-5-93 Smrproxy.nlm were
- loaded, fileserver utilization might increase and possibly no one could
- login.
-
- 6. Locksets were not released with SMRAGENT 2-14-94, byte count 29,776.
-
- 7. When INSTALL is loaded at the fileserver, the fileserver would sometimes
- abend (occurred with SITEMETR.NLM 2-13-94 and SMRPROXY.NLM 2-14-94).
-
- 2.2.6 SMRUP3.EXE 05-25-94 1,788,902 11:48a
-
- On 5-25-94 the SMRUP2.EXE patch was released. IT IS ONLY APPLICABLE TO
- SITEMETER v. 4.10 USERS. IT IS NOT APPLICABLE TO SITEMETER v. 4.00 USERS.
- SMRUP3 is a self-extracting file dated 5-25-94 and contains the following
- files:
- o READ1ST.TXT 9,714 05-18-94 11:27a
- o SITEMTR.EXE 1,774,855 05-17-94 5:17p
-
- SITEMTR.EXE consists of the following files:
- o DPRODREG.EXE 77,437 03-18-94 2:10p; used for serialization only
- o FIELD .DDF 55,296 04-28-94 11:27a
- o FILE .DDF 7,680 04-28-94 11:27a
- o SITEMETR.EXE 1,175,568 05-09-94 5:54p
- o FUSION .CFG 55 11-15-93 7:05p; used for serialization only
- o INDEX .DDF 11,776 04-28-94 11:27a
- o NWCALLS .DLL 146,544 11-02-93 2:30p
- o NWIPXSPX.DLL 38,544 11-02-93 5:47p
- o NWLOCALE.DLL 38,576 11-02-93 6:12p
- o NWNET .DLL 205,104 11-02-93 5:12p
- o NWNETAPI.DLL 106,884 01-07-93 1:31p
- o SERIAL .BAT 32 03-17-94 4:33p; used for serialization only
- o SITEMETR.NLM 351,108 05-04-94 12:12p
- o SMRAGENT.EXE 21,168 04-01-94 1:26p
- o SMRPROXY.NLM 74,972 05-04-94 12:18p
- o US_AD .RPT 17,008 03-22-94 4:57p
- o VENDOR .LIS 1,745 03-31-93 11:36a
- o UFLBWRKS.DLL 32,640 05-03-94 05:03p
- o CHISHWSV.RPT 25,951 05-04-94 02:51p
- o CHISHWMC.RPT 23,809 05-04-94 03:03p
- o CHISHWPC.RPT 25,423 05-04-94 11:05a
- o UPF .RPT 9,562 03-22-94 04:39a
- o US .RPT 14,949 03-22-94 04:44p
- o US_AS .RPT 15,853 03-24-94 04:05p
- o SPA .RPT 7,942 03-22-94 04:35p
- o SWINAPP .EXE 49,680 05-04-94 12:06p
- o SREPORT .EXE 116,752 05-09-94 05:30p
- o SYSMOD .EXE 44,192 05-04-94 12:08p
- o USAGE .EXE 130,064 05-04-94 01:44p
- o SDUPDATE.EXE 136,736 05-04-94 11:55p
- o SA_EQUIP.EXE 272,421 05-02-94 04:35p
- o WSDUPD .EXE 21,504 05-04-94 12:03p
- o EQUIP .EXE 174,607 05-02-94 04:17p
- o CRW .EXE 1,768,448 05-04-94 04:56p
- o QUICKST .WRI 17,536 05-09-94 10:37a; a guide to getting started
- o DELID .EXE 16,318 05-04-94 11:35a
- o SPF .RPT 9,622 03-22-94 04:38p
- o AS_UD .RPT 18,218 03-22-94 03:36p
- o AS .RPT 14,318 03-22-94 03:38p
- o AS_US .RPT 16,592 03-22-94 04:13p
- o WSREPOT .RPT 26,961 04-22-94 04:51p
- o METERDEF.RPT 7,416 03-23-94 05:03p
- o BDIABOUT.DLL 424,464 05-11-94 12:34p
- o SMRXPORT.DLL 67,628 04-17-94 04:46p
- o README .TXT 36,144 05-13-94 01:37p; updated with the new changes
- o SMR .BAT 158 05-17-94 02:26p; to remove old files
-
- SITEMETR.EXE contains updated NLMs, DLLs, and EXEs for BrightWorks v1.0.1,
- LAN Automatic Inventory 3.1.1 and SiteMeter v4.1.1. (Please note that the
- NLMs and SMRAGENT.EXE included here are the same versions of those files
- that are contained within FUSUP3.EXE of PCVEND LIB3). The updated version
- of SMRAGENT.EXE included here addresses an "out of memory" message that could
- display in Windows (Occurred with SMRAGENT 3-09-94). Also included in
- SITEMTR.EXE are updated Data Dictionaries (DDFs). These DDFs now combine
- Inventory and Metering data structures into the same group of definition
- files. In addition, an update to the canned Metering report "Application
- Use with User Detail" (US_AD.RPT) addresses an issue wherein the Date could
- appear in the Time Out field.
-
- It also includes an updated message file for the SiteMeter NLMs. The
- following list details what other fixes are included in this patch. These
- errors sometimes occurred with SiteMeter v. 4.0 and the patches released up
- to, but not including, SiteMeter v. 4.1:
-
- 1. Sometimes cannot meter or virus protect applications run from a map
- rooted drive.
-
- 2. SMRPROXY NLM cannot be loaded without first disabling NetWare Accounting.
-
- 3. The fileserver would sometimes abend upon a DOWN command.
-
- 4. Sometimes a SPX socket problem occurred with SMRAGENT 8-17-93.
-
- This sometimes occurred with other programs that open SPX sockets inside
- Windows such as a mail TSR or Windows For Workgroups. Symptoms include,
- "SiteMeter agent Error 7: There was an IPX Problem communicating with
- server" or "Wcnwlib error: Unexpected error opening socket" or PC lock
- ups. This problem also results in "Error 001: cannot communicate with
- VAP or NLM" with the SiteLock Swrap feature.
-
- 5. IPX Traffic. Sometimes when the 7-20-93 Sitemetr.nlm and the 8-5-93
- Smrproxy.nlm were loaded, fileserver utilization might increase and
- possibly no one could login.
-
- 6. Locksets were not released with SMRAGENT 2-14-94, byte count 29,776.
-
- 7. When INSTALL is loaded at the fileserver, the fileserver would sometimes
- abend (occurred with SITEMETR.NLM 2-13-94 and SMRPROXY.NLM 2-14-94).
-
- SiteMeter v. 4.1.1 contains these updated files:
- o SMRPROXY.NLM 74,972 5-04-94
- o SITEMETR.NLM 351,108 5-04-94
- o SMRAGENT.EXE 21,168 4-01-94
- o SITEMETR.MSG 1,439 2-10-94
-
- 2.2.7 SiteMeter Reports (Sreport.exe)
-
- As of this writing, SREPORT.EXE 5-9-94, 116,752 bytes is the current
- SiteMeter Report file. It ships with SiteMeter v. 4.1.1. It is available
- in a patch file SMRRPT3.EXE which is on Compuserve, GO BRIGHT, LIB 3.
-
- 1. "Sreport caused a GPF in module DLWBC31.DLL".
-
- A General Protection Fault error occurs when a user Exports a 65K or
- greater Sitedata file to non-btrieve format (i.e., Excel, etc.). This
- is an open issue currently under investigation. To workaround the issue,
- rename the Sitedata file before it reaches 65K in size.
-
- 2. Btrieve error code 20, cannot run Sreport".
-
- This means that SREPORT.EXE detected that Btrieve was not loaded properly.
- o Local Btrieve or brequest.exe are INDEED not loaded.
- o SPX is not loaded (when using brequest and server btrieve. IPXODI
- has the option of disabling SPX. Enable SPX). Make sure IPXODI
- is NOT loaded with a /d or /a switch. /d prevents IPXODI from
- loading SPX.
- o BSPXCOM.NLM is not loaded.
- o Ensure that VIPX.386 is version 1.17 or later if IPXODI is being
- loaded high. If VIPX.386 is version 1.1 and IPXODI is loaded high,
- the SPX could fail and cause the BTRIEVE error 20.
- o Make sure the NOVDB.INI file exists in the \Windows directory.
- o If the user is attached to multiple fileservers, have them log
- into just the one server where SiteMeter/BrightWorks is installed.
-
- 3. Sreport caused a GPF in module CRPE.DLL @ 0026:0A03".
-
- Resolved by SREPORT 5-9-94, byte count 116,752. Get SMRUP3.EXE file
- from Compuserve.
-
- 4. No information shows in a SiteMeter report done for a date range of one
- day.
-
- For a workaround, do a report with a date range greater than one day.
- This is an open issue that is currently being investigated.
-
- 5. Peaks calculation problem.
-
- Resolved by SREPORT 5-9-94, byte count 116,752. Get SMRUP3.EXE file
- from Compuserve.
-
- 6. "Unanticipated Btrieve Error #1".
-
- User gets this error if they use Brequest v. 6.10d. This error also
- occurs with BREQUEST.EXE v6.10e. Use Brequest v. 6.10c, or later,
- instead. Btrieve v. 6.10c is available on Compuserve. GO NOVLIB,
- Library 7 and download the file BTR61.EXE.
-
- 7. Negative number problem.
- User gets negative numbers in the report data. First addressed by
- SREPORT 3-24-94. Get SMRUP3.EXE file from Compuserve.
-
- 8. An update to the "canned" report file US_AD.RPT resolved an issue
- wherein the Date could appear in the "Time Out" field of the "Application
- Use with User Detail" report.
-
- First addressed on 3-15-94. Get SMRUP3.EXE file from Compuserve.
-
- 9. The "Defined Limit" field of the Metering Definitions could reflect an
- incorrect value.
-
- First resolved with 3-24-94 Sreport. Get SMRUP3.EXE file from Compuserve.
-
- 10. A GPF that could be caused by UFLSAMP1.DLL.
-
- First resolved with Sreport 3-24-94. Get SMRUP3.EXE file from Compuserve.
-
- 11. The SMRPT2.EXE file included updated .dll files so as to be in sync with
- the same files that existed in the Fusion v1.00 package and in
- FUSUP2.EXE patch file on Compuserve, LIB3, PCVEND.
-
- SMRUP3.EXE patch contains these files as well.
-
- 12. GPF caused by UNIDRV.DLL.
-
- SiteMeter reports would give a GPF in UNIDRV.DLL when the Printer Icon
- was used to print from an open report window and the user then exited
- and re-entered the SiteMeter reports. This is an OPEN issue. The
- workaround is to either close all of the open report windows before
- exiting SiteMeter Reports or to have the user downgrade to an earlier
- version of UNIDRV.DLL.
-
- 13. Corrupt Sitedata file?
-
- When the SiteMeter Reports fail, another possibility is that the
- SITEDATA file has become corrupt (or SITEDATA does not exist because no
- one has been metered yet and caused SITEDATA to be created by the NLMs).
- A quick method of verifying this is to divide the byte size of the
- Sitedata file by 49. If the result is not a round number, the file is
- corrupt. The Sitedata Debugger program may be used to fix the file.
- To have the Debugger come up in SREPORT, create a SREPORT.INI file
- in the \WINDOWS directory.
-
- It should contain,
- [Debug]
- Enabled=1
- file type=10
- An alternative is to send the Sitedata file to McAfee East Tech Support
- by Compuserve or the mail so we can fix it with the Sitedata Debugger
- program.
-
- 2.2.8 BTRIEVE
-
- This section contains common SiteMeter Btrieve errors and solutions.
-
- 1. "Btrieve record manager inactive".
-
- Have the user type PATH. This will show all of their search drives.
- Then have the user do a dir on WBTRCALL.DLL in each of the search drives.
- If they come across another copy of WBTRCALL.DLL it means the user may be
- loading the wrong WBTRCALL.DLL file for Btrieve.
-
- 2. User runs the SiteMeter reports and gets "Unable to allocate memory for
- Btrieve".
-
- This error is caused by not having enough free conventional memory.
- a. Load BREQUEST in the WINSTART.BAT file so it does not load in
- conventional memory.
- b. Free up some conventional memory and restart (i.e. remove TSRs,
- etc.). It has been reported that about 508K of free memory is
- needed to run the SiteMeter Reports.
-
- 3. User runs the SiteMeter Reports and gets "Page Size Error - Btrieve
- error 24".
- a. The user must run BREQUEST or BTRIEVE at the workstation.
- b. Free up memory. Load items high (LSL, NIC driver, etc.) and/or
- load BREQUEST into high memory by loading it in the WINSTART.BAT file.
-
- 2.2.9 Changing the SiteMeter Messages
-
- A user may request to change the text of a message in SiteMeter.
- The method to do this is to go into the SYS:SYSTEM\SITEMETR directory (or
- wherever the Home Directory For Data Files are located. Go Administration,
- Metering, Configuration Options). Then have the user make a backup of the
- SITEMETR.MSG file. They can then use a text editor to change the messages.
- Then the user must reload the SiteMeter NLMs.
-
-